您的位置: 专家智库 > >

国家自然科学基金(20375012)

作品数:5 被引量:15H指数:2
相关作者:史爱武阳明辉沈国励渠凤丽俞汝勤更多>>
相关机构:湖南大学更多>>
发文基金:国家自然科学基金更多>>
相关领域:理学生物学医药卫生自动化与计算机技术更多>>

文献类型

  • 5篇期刊文章
  • 5篇会议论文

领域

  • 5篇理学
  • 4篇自动化与计算...
  • 3篇生物学
  • 2篇医药卫生

主题

  • 3篇USING
  • 2篇FABRIC...
  • 2篇INTERF...
  • 2篇NANOPA...
  • 2篇PHENOL...
  • 2篇SOL-GE...
  • 1篇定量构效关系
  • 1篇荧光动力学
  • 1篇人血浆
  • 1篇溶胶
  • 1篇溶胶-凝胶
  • 1篇肾上腺
  • 1篇肾上腺素
  • 1篇生物传感
  • 1篇生物传感器
  • 1篇碳纳米管
  • 1篇偏最小二乘
  • 1篇去甲肾上腺
  • 1篇去甲肾上腺素
  • 1篇最小二乘

机构

  • 4篇湖南大学

作者

  • 4篇俞汝勤
  • 3篇吴海龙
  • 2篇沈国励
  • 1篇渠凤丽
  • 1篇阳明辉
  • 1篇朱绍华
  • 1篇周燕平
  • 1篇韩清娟
  • 1篇夏阿林
  • 1篇蒋健晖
  • 1篇唐丽娟
  • 1篇史爱武

传媒

  • 2篇Chines...
  • 2篇Chemic...
  • 2篇第九届全国计...
  • 1篇分析科学学报

年份

  • 2篇2008
  • 3篇2007
  • 1篇2006
  • 4篇2005
5 条 记 录,以下是 1-10
排序方式:
ELECTROCHEMICAL BIOSENSORS FOR PHENOLS: THE ENZYME IMMOBILIZATION AND INTERFACE FABRICATION USING NANOPARTICLES AND SOL-GELS
Phenolic compounds are important contaminants in environment mainly from wastewaters of industries and petrole...
Ruqin YUZhimin LIUYingfeng LIGuoli SHEN
基于蒙特卡洛无信息变量消除的波长选择方法
在现代光谱分析中,波长选择方法是相当重要的预处理过程。针对多元校正中光谱数据分析中存在的大量不相关波长变量,提出了一种消除无信息变量的方法—蒙特卡洛无信息变量消除方法(MCUVE),该方法将蒙特卡洛过程与无信息变量消除方...
韩清娟吴海龙俞汝勤
关键词:波长选择偏最小二乘
文献传递
基于掺杂碳纳米管的复合体系电化学生物传感器研究被引量:9
2008年
制备了含有铂纳米颗粒(NSPt)的壳聚糖(CHIT)和正硅酸四乙酯(TEOS)溶胶-凝胶溶液,将多壁碳纳米管(MWCNTs)分散于制备的CHIT和TEOS溶胶-凝胶混合物体系,并用高倍透射电镜(TEM)和扫描电子显微镜(SEM)对NSPt-CHIT表面和MWCNTs进行了表征。此种复合膜修饰玻碳电极对过氧化氢有灵敏的电化学响应。通过在此复合膜修饰的玻碳电极上固定葡萄糖氧化酶(GOx)制备了葡萄糖生物传感器。该传感器对葡萄糖在0.05~8mmol/L范围有线性响应,相关系数为0.996,检出限(S/N=3)为10umol/L。传感器对葡萄糖有灵敏响应,并有很好的重现性和稳定性,应用于实际样品体系的回收试验,结果良好。
渠凤丽史爱武阳明辉沈国励俞汝勤
关键词:碳纳米管铂纳米颗粒溶胶-凝胶生物传感器
Amplified Electrochemical Immunoassay Using HRP Labeled Protein as an Inhibitor to Silver Deposition in the Presence of H_2O_2
2006年
A novel electrochemical immunosensor with amplification effect based on the enzyme inhibition of silver deposition was proposed. In this method, the capture antibody was first immobilized onto a gold electrode via a self-assembled layer. After a sandwich immunoreaction, HRP labeled antibody was bound to the gold electrode. The HRP on the electrode inhibited silver deposition when the electrode was incubated in hydroquinone-H2O2 solution and silver ion solution. The linear sweep voltammetry was chosen to detect the deposited silver and the result showed that the peak current was linearly proportional to the content of IgG in the range of 50 to 2500 ng/mL with a detection limit of 35 ng/mL.
Zhao Peng CHEN Jian Hui JIANG Xiao Bing ZHANG Guo Li SHEN Ru Qin YU
关键词:IMMUNOSENSOR
Aptamer-based Electrochemical Biosensors for Highly Selective and Quantitative Detection of Adenosine被引量:6
2008年
A new adenosine biosensor based on aptamer probe is introduced in this article. An amino-labeled aptamer probe was immobilized on the gold electrode modified with an o-phenylenediamine electropolymerized film. When adenosine is bound specifically to the aptamer probe, the interface of the biosensor is changed, resulting in the decrement of the peak current. The response current is proportional to the amount of adenosine in sample. The used electrode can be easily regenerated in hot water. The proposed biosensor represents a linear response to adenosine over a concentration range of 1.0x 10^-7-l.0x10^-4 mol/L with a detection limit of 1.0xl0^-8 mol/L. The presented biosensor exhibits a nice specificity towards adenosine. It offers a promising approach for adenosine assay due to its excellent electrochemical properties that are believed to be very attractive for electrochemical studies and electroanalytical applications.
ZHENG Fan WU Zai-sheng ZHANG Song-bai GUO Meng-meng CHEN Chen-rui SHEN Guo-li YU Ru-qin
关键词:ADENOSINEAPTAMER
Electrochemical Detection of Clenbuterol in Pig Liver at Pyrrole DNA Modified Boron-doped Diamond Electrode
2005年
The direct detection of clenbuterol(CL) in pig liver without any extraction separation at a pyrrole-DNA modified boron-doped diamond(BDD) electrode is reported. The pyrrole-DNA modified BDD electrode has a strong electrocatalytic effect on the redox reaction of CL. One oxidization and two reduction peaks of CL appear at 340. 2, 299. 8 and 166. 6 mV( versus SCE), respectively. The pyrrole polymer alone cannot electrocatalyze the above reaction at a BDD electrode ; the electrocatalytic effect of a BDD electrode modified with DNA membrane is unsufficient for the analytical detection of CL; the replacement of boron-doped diamond by glass carbon makes the electrocatalytic reaction impossible ; the redox process is pH dependent. The influences of various experimental parameters on the pyrrole-DNA modified BDD electrode were investigated. A sensitive cyclic vohammetric response for CL was obtained in a linear range from 3.4 × 10^-6 to 5 × 10^ -4 mol/L with a detection limit of 8.5 × 10^-7 mol/L. A mean recovery of 102. 7% of CL in the pig liver sample solution and a reproducibility of 3.2% were obtained.
WU JingLI Xiao-liWU Xu-meiHUAN Shuang-yanSHEN Guo-liYU Ru-qin
荧光动力学结合二阶校正法定量测定人血浆中的去甲肾上腺素
本文提出了荧光动力学结合二阶校正法实现人血浆中去甲肾上腺素定量测定的新方法.去甲肾上腺素本身的荧光较弱,在碱性溶液中可以被氯化生成强荧光化合物。本文利用这一特性,在 pH 值为9.06的硼酸缓冲液的缓冲作用下采用铁氰化钾...
李淑芳吴海龙夏阿林朱绍华聂瑾芳边英超刘佳俞汝勤
关键词:去甲肾上腺素光动力学二阶校正
文献传递
ELECTROCHEMICAL BIOSENSORS FOR PHENOLS: THE ENZYME IMMOBILIZATION AND INTERFACE FABRICATION USING NANOPARTICLES AND SOL-GELS
<正>Phenolic compounds are important contaminants in environment mainly from wastewaters of industries and petr...
Ruqin YUZhimin LIUYingfeng LIGuoli SHEN
A Novel Biomolecular Immobilization Matrix Based on Nanoporous ZnO/Chitosan Composite Film for Amperometric Hydrogen Peroxide Biosensor
2005年
MingHuiYANGJianHuiJIANGGuoLiSHENRuQinYU
关键词:CHITOSAN
粒子群优化算法用于训练基于径向基函数网络变换的非线性支持向量机及其QSAR研究应用
支持向量机(SVM)因其函数逼近功能以及显著的泛化能力在 QSAR 研究中得到了越来越多的关注。但是,非线性支持向量机中支持向量的选择和过度的核半径优化使其易于陷入局部最优,增加了欠拟合或过拟合发生的风险。为了克服这些问...
唐丽娟周燕平蒋健晖吴海龙沈国励俞汝勤
文献传递
共1页<1>
聚类工具0