您的位置: 专家智库 > >

国家自然科学基金(11005143)

作品数:2 被引量:5H指数:1
发文基金:国家自然科学基金国家重点基础研究发展计划更多>>
相关领域:理学机械工程更多>>

文献类型

  • 2篇中文期刊文章

领域

  • 2篇机械工程
  • 2篇理学

主题

  • 1篇束线
  • 1篇小角X射线散...
  • 1篇光束
  • 1篇光束线
  • 1篇SAXS
  • 1篇SSRF
  • 1篇WAXS
  • 1篇CYLIND...
  • 1篇EDGE
  • 1篇STREAK
  • 1篇EQUATO...
  • 1篇SMALL-...
  • 1篇SCATTE...
  • 1篇BEAMLI...

传媒

  • 1篇Chines...
  • 1篇Nuclea...

年份

  • 1篇2015
  • 1篇2013
2 条 记 录,以下是 1-2
排序方式:
Quantitative evaluation of equatorial small-angle X-ray scattering for cylindrical fibers
2013年
Elongated microvoids, internal fibrillar structure, and edge scattering from both surface refraction cause an equatorial streak in small angle X-ray scattering. A model for analyzing the edge scattering of fibers is proposed. Simulation results indicate that the intensity of edge scattering from surface refraction of a cylindrical fiber is strong and makes an important contribution to the equatorial streak. Two factors influence edge scattering intensity. One is the sample-to-detector distance (D); edge scattering intensity increases with increasing D. The equatorial streak becomes weak when D is shortened. The other factor is the refraction index. Edge scattering intensity increases as the real component of the refraction index decreases. In experiment, weak or even no equatorial streaks were found for samples measured in a roughly index-matching fluid. Edge scattering can be eliminated or weakened, and it can be calculated by comparing the intensities of a cylindrical fiber when it is measured in air and in index-matching fluid. The simulation data are basically in agreement with the experimental data.
李小芸李秀宏杨春明滑文强赵镍缪夏然田丰王玉柱边风刚王劼
Small angle X-ray scattering beamline at SSRF被引量:5
2015年
Beamline BL16B1 at Shanghai Synchrotron Radiation Facility(SSRF) is dedicated to studying the microstructure and dynamic processes of polymers, nanomaterials, mesoporous materials, colloids, liquid crystals,metal materials, etc. At present, SAXS, wide angle X-ray scattering(WAXS), simultaneous SAXS/WAXS,grazing incident SAXS, and anomalous SAXS techniques are available for end user to conduct diverse experiments at this beamline. The sample-to-detector distance is adjustable from 0.2 m to 5 m. The practicable q-range is 0.03–3.6 nm-1at incident X-ray of 10 ke V for conventional SAXS whilst a continuous q-region of0.06–33 nm-1can be achieved in simultaneous SAXS/WAXS mode. Time-resolved SAXS measurements in sub-second level was achieved by the beamline upgrating in 2013. This paper gives detailed descriptions about the status, performance and applications of the SAXS beamline.
田丰李秀宏王玉柱杨春明周平林金友曾建荣洪春霞滑文强李小芸缪夏然边风刚王劼
关键词:小角X射线散射光束线SAXSWAXSSSRF
共1页<1>
聚类工具0