In this paper,a method of choosing mixture medium in two-cell stimulated Brillouinscattering(SBS)system to improve the system performance is proposed.The Brillouin frequency shift(BFS)of mixture medium varies with the mixing ratio andthus the difference of the BFS between the two cells can be eliminated.The two-cellSBS system with acetone(C3H6O)in its generator cell and mixture liquid ofCCl4/C2Cl4 in its amplifier cell is investigated.The C3H6O has a high optical breakdown threshold and the mixture liquid of CCl4/C2Cl4 has a small absorption coeffi-cient and the same BFS as that of C3H6O when the volume fraction of CCl4 is 4%.Compared with two-cell SBS system with the same liquid(C2Cl4)or different liquid(C3H6O and C2Cl4)in generator and amplifier cell,the SBS system with mixture liq-uid(CCl4/C2Cl4)in amplifier cell and C3H6O in generator cell improves thepower-load,energy reflectivity(ER),phase conjugation(PC)fidelity and ER stabil-ity.
In order to measure the Brillouin frequency shift (BFS) of the medium, this paper proposes a method using mixtures in a two-cell stimulated Brillouin scattering system, which uses a medium to be measured as amplifier medium and a mixture medium as generator medium. The seed light from the generator gains effective amplification in the amplifier and the amplification ratio changes with the mixing fraction, Only when the BFS of the mixture medium is equal to that of the medium in the amplifier does the seed light obtain the maximum amplification ratio. The method has the advantage of independence of the wavelength of the incident light.